Search   Start
Our Product Recommendations for Cement Plants

The table below shows an overview over measuring points in a coal-fired cement plant based on the dry process. The data is completed by the measuring tasks and the recommended analyzer devices of our program. In practice, deviations from this example however can arise.

Recommended products
Measuring point   Tasks   Suitable analyzers   
Raw material silo, raw meal silo Level monitoring MaihakMBA200, MaihakLOT369
Behind preheater Optimization of the burner, reduction of nitrogen oxides S700
Behind calciner Optimization of the secondary firing, monitoring of the calcination S700
Kiln inlet Optimization of burner and product quality SCP3000, S700, MCS100E
Additives silos, cement silo Level monitoring MaihakMBA200, MaihakLOT369
Behind exhaust gas fan, in front of electrostatic filter Protection of electrostatic filter against explosions, cooling water control GM950, S700, FLOWSIC100, SIDOR
Behind gas cleaning, in flue gas ducts and exhaust gas stack Emission monitoring GM31, ZIRKOR302, GM901, S700, MCS100FT, MCS100E, EuroFID, MERCEM, OMD41, RM230, RM210, FW100, FLOWSIC100
Exhaust gas stack Emission data acquisition and processing MEAC2000
Coal silo, in front of coal mill False air entry in case of inert gas operation, level monitoring S700, SIDOR, ZIRKOR302, MaihakMBA200, MaihakLOT369
Behind coal mill False air entry control, protection against smouldering S700, SIDOR, ZIRKOR302
Coal dust silo Protection against smouldering, level monitoring S700, SIDOR, MaihakMBA200, MaihakLOT369


Contact
SICK MAIHAK GmbH
Central Sales Office
Nimburger Strasse 11
79276 Reute
Germany

Phone
+49 7641 469-0
Fax
+49 7641 469-1149