Search   Start
 
FW100
 
 
Dust concentration monitor
Where other technologies fail, the FW100 from SICK MAIHAK comes into its own! Thanks to the scattered-light measurement integrated in its probe, the FW100 can measure even minimal dust concentration levels precisely independent of the gas velocity. No mechanical adjustments or calibration to a dust-free measuring path are necessary.
Applications
Monitoring emission limit values; monitoring hose filter systems; workplace monitoring
 
Technical specification
  Measuring values   Scattered-light intensity, dust concentration in mg/m3  
  Measuring range   Min.: 0 ... 5 mg/m3
max.: 0 ... 200 mg/m3
 
  Duct inner diameter   FW101: 250 mm and higher
FW102: 150 mm and higher
 
  Measurement principle   Scattered light (forward scattering)  
  Measuring gas temperature   FW101: up to 400 °C
FW102: up to 220 °C
 
  Compliance   Approved according to Federal German Pollution Control Act (13th, 17th and 27th Implementing Ordinance), German Clean Air Regulations (TA Luft)  
  Interfaces   RS232  
  Protection category   IP65  
  Measured value output   0/2/4 ... 20 mA analog output  
  Status / control signals   Relay outputs for binary signals  
  System modules   Transmitter/receiver unit, connection unit with integrated air purge unit  
  Test function   Automatic zero and check point  
     
Shopping Cart
Info service