FW56 I
|
|
| |
Filter Watch
Applications Dust concentration monitoring after filter plants
|
|
 |
 |
 |
 |
 |
Technical specification |
 |
 |
| |
Measuring values |
|
Transmittance, differential transmittance, dust concentration, extinction, dynam. extinction, opacity |
|
 |
 |
 |
| |
Measuring range |
|
transmittance: 0 ... 100 %
diff. transmittance: 0 ... 100 %
opacity: 0 ... 100 %
extinction: 0 ... 2 |
|
 |
 |
 |
| |
Measurement principle |
|
Transmittance |
|
 |
 |
 |
| |
Compliance |
|
TÜV approved for filter separator |
|
 |
 |
 |
| |
Protection category |
|
IP 65 |
|
 |
 |
 |
| |
Measured value output |
|
0/2/4 ... 20 mA analog output |
|
 |
 |
 |
| |
Interfaces |
|
RS232, RS422 |
|
 |
 |
 |
| |
Status / control signals |
|
Relay outputs for status signals |
|
 |
 |
 |
| |
System modules |
|
Transmitter/receiver unit, evaluation unit, air purge unit |
|
 |
 |
 |
| |
Test function |
|
Automatic zero and check point |
|
 |
 |
 |
| |
Remarks |
|
- High resolution due to the use of dynamic transmittance and dynamic extinction.
- Simple installation and commissioning
- Low maintenance expenditure
|
|
 |
 |
 |
| |
|
|
|
|
 |
|
 |
|