FLOWSIC150 CARFLOW
|
|
| |
The FLOWSIC150 CARFLOW is a measurment system which has been specially adapted to the requirements of exhaust gas volume measurement on roll test stands and road test simulators in the automotive industry.
This compact measuring system can easily be connected to existing exhaust gas hose systems using quick connectors and is assembled on lockable rolling wheels for transportable use.
The volume flow is measured in the undiluted exhaust gas. For high accuracy measurements the instrument is available in a multi-path configuration (3 and 4 ultrasound measuring paths). The 4-path version has an additional enlargerd measuring range.
Integrated sensors for pressure and temperature determine these parameters directly in the measuring cell and are used for calculating and outputing the exhaust gas volume in the normalized state.
|
|
 |
 |
 |
 |
 |
Technical specification |
 |
 |
| |
Measuring values |
|
gas velocity, volume flow (o.s.), volume flow (s.s.), gas temperature, absolute pressure, sound velocity |
|
 |
 |
 |
| |
Measuring range
(actual volumetric flow) |
|
1 and 3 measuring paths:
0 ... 150 l/s, 70 mm inner pipe diameter
4 measuring paths:
0 ... 300 l/s, 100 mm inner pipe diameter
other pipe diameters / higher flow rates on request |
|
 |
 |
 |
| |
Pulse rate |
|
1 x 80/s (1 path)
3 x 30/s (3 paths)
4 x 30/s (4 paths) |
|
 |
 |
 |
| |
Accuracy typical |
|
< ±2.5 % of measured value, 0.1 Qmax ... Qmax (1 path)
< ±0.7% of measured value, 0.05 Qmax ... Qmax (3 paths)
< ±0.5% of measured value, 0.05 Qmax ... Qmax (4 paths) |
|
 |
 |
 |
| |
Measuring range pressure |
|
660 ... 1100 hPa |
|
 |
 |
 |
| |
Gas temperature |
|
max. 300 °C (< 10min/h for max. 100 cycles), higher values on request |
|
 |
 |
 |
| |
Transducer temperature |
|
max. 280 °C, higher values on request |
|
 |
 |
 |
| |
Ambient temperature |
|
-20 ... +50 °C |
|
 |
 |
 |
| |
Measured value output |
|
0 / 2 / 4 ... 20 mA, max. load 760 Ohm,
update rate 10/s |
|
 |
 |
 |
| |
Interfaces |
|
RS232 (Modbus/AK): update rate 10/s
RS232: programmable update rate, for parameter setting via PC |
|
 |
 |
 |
| |
Process connection |
|
thread G 2 1/2" (1 and 3 paths),
thread G 4" (4 paths),
others on request |
|
 |
 |
 |
| |
Power supply |
|
90 ... 140 V AC, 50/60 Hz or 190 ... 260 V AC, 50/60 Hz, adjustable,
approx. 700 W (1 and 3 paths)
approx. 1100 W (4 paths) |
|
 |
 |
 |
| |
|
|
|
|
 |
|
 |
|