VICOTEC450
 
 
Extractive visibility measurement
The VICOTEC450 offers optimal solution for visibility measurement if
  • fixtures in the tunnel tube are not permitted or not possible due to lack of space
  • fog should not be included in the visibility measurement
The VICOTEC450 regularly and automatically carries out a functional test including the control point, zero point, the function of the laser and receiver as well as the contamination of the optical surfaces.
Maintenance requirements for cleaning and filter exchange are automatically registered and signalled in good time by the VICOTEC450 due to contamination monitoring of the front panel and measurement of the air flow rate (optional).
 
Technical specification
  Measuring values   Visibility  
  Measuring range   0…15 1/km  
  Repeatability   ±2 % of measuring range  
  Measuring principle   Laser light forward scattering below 25°
in the extracted heated air
 
  Ambient temperature   –30…+55 șC  
  Protection category   IP 66  
  Measured value output   0…20 mA  
  Interfaces   USB, RS232
option: Profibus DP (uni-directional), LAN, RS485, RS422, fibre optics
 
  Status-/control signals   5 relay outputs, 2 analog inputs, 4 digital inputs
optional: modules for further inputs and outputs
 
  System components   Measurement unit VCME with integrated suction, control unit MCU  
  Test function   Automatic self test for linearity, contamination, drift and aging  
  Remarks   The VICOTEC450 draws air from inside the tunnel, heats it over the dew point and determins the visibility by using scattered light technology.  
     