MCS100
|
|
| |
Multi-component process photometer for gase and liquids Process control in corrosive and toxic gases or liquids. The MCS100 is equipped with a very robust singlebeam process photometer for performing process measurements in the UV, VIS, (N)IR spectral range. Up to 8 components can be measured continuously with one MCS100. It is also possible to offset disturbance variables. Cells ranging from the 0.1 mm high-pressure liquid cell to the compact 6 m high-temperature long-path cell are available.
Applications Process control of gases and liquids with problematic components; high pressure; high temperature; suitable for use in explosive atmospheres (option)
|
|
 |
 |
 |
 |
 |
Technical specification |
 |
 |
| |
Measuring components |
|
UV/VIS/(N)IR absorbing gases and liquids, e.g. Cl2, SO2, CO2, NH3, H2O, C2H4, C2H4Cl2, COCl2, NCO, C2H4, CH3SH, H2S, HCl ... |
|
 |
 |
 |
| |
Number of components |
|
max. 8 |
|
 |
 |
 |
| |
Measuring range |
|
ppm to vol% dep. on application, 2 ranges |
|
 |
 |
 |
| |
Measurement principle |
|
Photometer, dual wavelength and gas filter correl. |
|
 |
 |
 |
| |
Ambient temperature |
|
0 ... +40 °C |
|
 |
 |
 |
| |
Protection category |
|
IP 65, special designs upon request |
|
 |
 |
 |
| |
Number of sample points |
|
max. 8 |
|
 |
 |
 |
| |
Measured value output |
|
24 * 0/4 ... 20 mA, 64 relays |
|
 |
 |
 |
| |
Interfaces |
|
RS232 (V 24) |
|
 |
 |
 |
| |
Status / control signals |
|
via digital inputs and outputs |
|
 |
 |
 |
| |
Test function |
|
Zero and span control automatically |
|
 |
 |
 |
| |
Remarks |
|
Very robust single-beam photometer for process analysis in UV/VIS/(N)IR spectral range. The correction of interferences is possible. Cells from 0.1 mm high pressure liquid cell to the compact 6 m high temperature long path cell are available. |
|
 |
 |
 |
| |
|
|
|
|
 |
|
 |
|